Instructions for the installer
3.17 - SYSTEM FILLING AND DRAINING
Warning!
Do not mix the CH system's water with anti-
freeze or anti-corrosion solutions using
wrong concentrations! It could cause dama-
ge to the washers and could provoke noise
during normal boiler operation.
UNICAL refuses all liability for injury to
persons, animals or damage to property
deriving from not having respected the above
mentioned recommendations.
After completing all the system's service connections the
circuits may be filled.
To fill the system it is necessary to fit a filling cock on the
system's return.
The boiler is equipped with its own drain tap, whose
position is indicated in the figure on page 17.
This tap must NEVER be used for draining of the whole
system as this could lead to system dirt gathering in the
boiler, compromising good boiler operation. Therefore, the
system has to be fitted with its own draining tap, of the right
size for the system's capacity.
GRUPPO DI
CARICAMENTO
EXAMPLE OF FILLING MANIFOLED
FILLING MANIFOLD